New

LiveGEL Imager 2.0

One tap from gel to report.

Slide the gel in, choose a light and tap Capture. LiveGEL straightens the image, finds the lanes, measures every band and builds a publication-ready report, all on its own.

Download brochure (PDF)
LiveGEL Imager 2.0 gel documentation system with its touchscreen

Tap once. The rest is automatic.

  1. Capture.
  2. Correct.
  3. Analyse.
  4. Report.
  5. Share.

Lane and band detection, densitometry, molecular weight and the PDF report all run on the instrument itself. No separate computer, no copying files across, no tracing bands by hand.

How it works

Three steps. The third is done for you.

The light, the filter, the photograph and the measurements are handled for you. Scroll to see what happens inside.

Inside the LiveGEL Imager 2.0Cutaway of the LiveGEL Imager 2.0. The gel slides in on a pull-out tray above a UV transilluminator. A 12 megapixel camera at the top looks straight down through a motorised filter wheel. A 10.1 inch touchscreen sits on the 60 degree front face.Closed cabinet10.1″ touchscreen at 60°UV transilluminatorPull-out gel trayGelMotorised filter wheel12 MP camera12 MP CAMERAMOTORISED FILTER WHEEL10.1″ TOUCHSCREEN AT 60°CLOSED CABINETGELPULL-OUT GEL TRAYUV TRANSILLUMINATOR
Inside the LiveGEL Imager 2.0Cutaway of the LiveGEL Imager 2.0. The gel slides in on a pull-out tray above a UV transilluminator. A 12 megapixel camera at the top looks straight down through a motorised filter wheel. A 10.1 inch touchscreen sits on the 60 degree front face.Closed cabinet10.1″ touchscreen at 60°UV transilluminatorPull-out gel trayGelMotorised filter wheel12 MP camera
Illustration. Proportions approximate.
  1. 1PlaceSlide the gel onto the pull-out tray and push the door shut.
  2. 2CaptureChoose a light on the touchscreen and tap Capture. The motorized filter wheel moves the matching filter into place, and the 12 MP camera picks the best exposure and takes the picture.
  3. 3Analysed for youLanes and bands are detected and measured automatically. Pick your ladder to size every band, then save the PDF report to a USB drive or scan the QR code to take it on your phone.

The numbers that matter.

12 MP Scientific camera for sharp, high-contrast gel images. Upgradable to 16 MP.
20 × 20 cm Images gels up to this size in one shot.
10.1″ Edge-sealed touchscreen, angled at 60°.
Auto bands Lanes and bands are detected and sized for you.
PDF + QR PDF reports, to a phone by QR code or to a USB drive.
3,000+ Analyses and images stored on the instrument.
Imaging

Faint bands, clearly seen.

Sharp, high-resolution pictures with strong contrast, right to the edges of the gel.

12 MP CMOS scientific camera · wide-aperture machine-vision optics · 20 × 20 cm field of view

Illustration: a gel lane whose faintest bands still show up as clear peaks in the intensity profile Position along the lane Intensity Faint bands, measured
Illustration.
Light

The right light for every stain.

Different stains glow under different light. Tap one on screen and the motorized filter wheel sets the optics for you. Choose a light below to see it.

UV 312 nm, blue light and white light come as standard. 254 nm and 365 nm are optional add-ons.

The same gel viewed under UV, blue and white light, side by side
Software

From picture to result, in one place.

Capture, correct, analyse, report and share, without moving the image to another computer first.

The LiveGEL analysis screen: lanes and bands detected on a gel, the intensity profile of lane 2, its bands sized in base pairs, and the ladder's standard curve
Automated lane and band detection Finds the lanes and bands in your gel for you.
Densitometric analysis Measures how strong each band is, as a share of its lane.
Molecular weight calculation Choose your ladder (1 kb, 100 bp or protein marker) and every band is sized for you.
Interactive 4-point lane warping Straightens lanes that ran crooked.
Smart capture Picks the best exposure and straightens a gel placed at a slight angle.
Publication-ready PDF report Scan the on-screen QR code to take it on your phone, or save it to a USB drive.
Design

Made for your lab.

60° displayThe 10.1″ touchscreen is angled for easy reading while standing.
Pull-out trayLoad and remove gels without reaching inside the cabinet. A push-to-close door seals it.
Automatic UV cut-offUV switches off the moment the door opens.
One plugA single 220 V AC, 50 to 60 Hz input.

Which LiveGEL is right for you?

You are here LiveGEL Imager 2.0 Photograph, measure and report finished gels.
  • 12 MP camera in a closed cabinet
  • Finds, measures and sizes bands for you
  • PDF reports by QR code or USB
Also new LiveGEL Viewer 2.0 Watch your bands while the gel is still running.
  • Your Amber tank fits inside, over blue light
  • Built-in power supply, with separate switches for light and power
  • Documentation hood with a filter, for photographing the gel on your phone
Explore Viewer 2.0 →

Looking for our original LiveGEL Imager? A dark-room cabinet with a 12 MP camera that saves your gel images to a computer. See the LiveGEL Imager →

Tech specs

MX-2140-05 Download brochure (PDF) →
Camera
12 MP CMOS scientific camera, upgradable to 16 MP
Optics
Wide-aperture machine-vision optics
Field of view
Up to 20 × 20 cm
Illumination, standard
UV 312 nm, blue light, white light
Illumination, optional
UV 254 nm, UV 365 nm
Filter selection
Motorized filter wheel
Display
10.1″ edge-sealed capacitive touchscreen, 60° angle
Gel loading
Pull-out tray, push-to-close door
Safety
UV switches off automatically when the door opens
Analysis
Lane and band detection, densitometry, molecular weight from 1 kb, 100 bp or protein ladders
Export
PDF report, by on-screen QR code or USB drive
Storage
3,000+ analyses and images
Power
220 V AC, 50 to 60 Hz, single input
Warranty
One year

Questions

What is a gel documentation system?

After gel electrophoresis, the DNA or protein bands are hard to see in normal light. A gel documentation system lights the gel and photographs it, so you have a clear, permanent record of your result to analyse and share.

Which light sources come as standard?

UV 312 nm, blue light and white light. UV 254 nm and 365 nm are available as optional add-ons.

How do I get my images out of the instrument?

Save the PDF report to a USB drive, or show a QR code on screen and scan it with a phone to download the report.

Do I need a computer?

No. Capture, analysis and the PDF report all run on the instrument and its touchscreen. Take your results away on your phone by QR code, or on a USB drive.

How many results can it store?

More than 3,000 analyses and images.

What power supply does it need?

A single 220 V AC, 50 to 60 Hz input.

What warranty does it carry?

One year, like every MEDOX instrument.

See it in your lab.

Add it to your Quick quote, or ask us for a demonstration. One-year warranty.

Ask for a demo

Send us your list. We’ll send a quote.

Search the catalogue, add what you need and send your list in one step. Or talk to our team.